- Which apparatus measures time and temperature in a reaction?
- A stop-watch measures time and a thermometer measures temperature. In the practical papers, times are recorded in whole numbers of seconds and temperatures to the nearest 0.5 °C. A digital thermometer has greater resolution, but it is not more accurate.
- Why is a burette more accurate than a measuring cylinder?
- A burette is more accurate than a measuring cylinder and can deliver variable volumes. Record each burette reading to 1 decimal place, such as 24.0 cm³. A volumetric pipette is also more accurate, but it measures one fixed volume only, such as 25.00 cm³. A measuring cylinder is quick but less accurate.
- How do I calculate the volume added from a burette?
- The volume added is the final reading minus the initial reading. The numbers on a burette increase downwards, so the final reading is always greater. For readings of 1.8 cm³ and 26.3 cm³, the volume added is 26.3 - 1.8 = 24.5 cm³.
- How do I measure the volume of a gas produced in a reaction?
- A gas syringe collects a gas and measures its volume. A measuring cylinder can also be used, but only over water, filled with water and inverted in a trough of water. Time the collection with a stop-watch, then divide the volume by the time to find the mean rate of reaction. Air already in the apparatus has no effect on accuracy.
- What is a saturated solution?
- A saturated solution contains the maximum concentration of a solute dissolved in the solvent at a specified temperature. A solvent is a substance that dissolves a solute, and a solute is a substance that is dissolved in a solvent. Leaving out the temperature loses the mark.
- Why do students confuse the residue and the filtrate?
- Many candidates put the residue in the collecting beaker and the filtrate in the funnel. The residue is the solid on the filter paper, and the filtrate is the liquid that passes through the filter. The filtrate is not the solid extracted from the mixture.
- What is the difference between a burette and a volumetric pipette?
- A burette can measure variable volumes, while a volumetric pipette measures a single volume, such as 25 cm³. A volumetric pipette is more accurate than a measuring cylinder. A burette adds the solution dropwise, whereas a volumetric pipette does not.
- Why is a burette rinsed with distilled water instead of tap water?
- Distilled water has fewer dissolved ions than tap water. Any water left in the burette must be removed before it is filled, because the water would dilute the solution. A greater volume would then be needed from the burette to reach the end-point.
- Why is Universal Indicator not suitable for a titration?
- Universal Indicator shows a series of gradual colour changes, so it has no sharp end-point. A suitable indicator has a sharp single colour change at the end-point, such as methyl orange.
- How do I identify the end-point of a titration?
- The end-point is reached when the colour of the indicator just changes. Add the solution from the burette dropwise and swirl the flask, because adding it quickly overshoots the end-point. A white tile under the flask makes the colour change easier to see.
- Why must the air below the burette tap be removed before a titration begins?
- The area below the tap is full of air. This air must be removed by running a little solution into a waste beaker before the titration begins. Saying that this checks the tap works is a common wrong answer.
- Does the rate of reaction affect a titration?
- No. A very common misconception is that titrations are linked to the rate of the reaction. The reactions used in titrations are almost instantaneous, so the rate is irrelevant. Warming the solution gives no change to the volume added.
- How do I separate coloured substances by paper chromatography?
- Draw a baseline in pencil and put a spot of the mixture on it. Stand the paper in a suitable solvent with the baseline above the solvent level. The solvent rises up the paper, and the substances travel different distances. A lid on the container prevents loss of the solvent.
- How do I identify an unknown substance using chromatography?
- Compare the unknown with known substances. A spot that travels the same distance as a known substance's spot is that substance. Compare the heights of the spots, not their colours. An unknown contains a known dye only if every spot of that dye matches a spot of the unknown.
- How do I calculate an Rf value?
- The Rf value is the distance travelled by the substance divided by the distance travelled by the solvent, both measured from the baseline in the same unit. It has no units. For a substance that travels 3.6 cm when the solvent travels 9.0 cm, Rf = 3.6/9.0 = 0.40.
- What does a chromatogram show about purity?
- A pure substance gives one spot, and an impure substance, a mixture, gives more than one spot. A substance that is insoluble in the solvent stays on the baseline. Count the spots in a column before judging a sample, because a spot that travels far can still belong to a mixture.
- How do I see colourless substances on a chromatogram?
- Colourless substances leave no visible spots, so a locating agent is used to make the spots visible. The method is otherwise the same, with a suitable solvent and different distances travelled. Amino acids are colourless, so a locating agent is needed when they are separated.
- Why do students get the Rf value wrong?
- Many candidates got the fraction the wrong way up. The distance travelled by the substance goes on top. The fraction upside down, 9.0 ÷ 3.6 = 2.5, is wrong.
- How do I separate sand from sodium chloride?
- Add a suitable solvent, such as water, so that the sodium chloride dissolves, then filter. The sand stays on the filter paper as the residue. The sodium chloride solution passes through as the filtrate.
- How do I obtain crystals from a solution?
- Heat the solution until it is saturated, at the point of crystallisation, then leave it to cool so that crystals form. Filter off the crystals, rinse them and dry them. Heating until all the water has gone is wrong, because copper(II) sulfate then gives a white solid.
- How does simple distillation separate water from sodium chloride?
- Heat the solution until the water boils. The water vapour condenses in the condenser and is collected, while the sodium chloride remains in the flask. Simple distillation separates a liquid from a mixture by its boiling point, and the liquid with the lower boiling point boils off first.
- How does fractional distillation separate a mixture of liquids?
- Fractional distillation separates a mixture of liquids that have different boiling points. The liquid with the lowest boiling point is collected first. For a mixture of three alkanes, pentane is collected first, and undecane stays in the flask because its boiling point is over 100 °C.
- How can I tell whether a substance is pure?
- A pure substance has a sharp melting point and boiling point, not a range of values. Impurities lower the melting point and raise the boiling point, so a melting point or boiling point can show whether a sample is pure. Pure water boils at 100 °C.
- Why is evaporating to dryness wrong when making crystals?
- It is wrong because heating until all the water has gone gives white anhydrous copper(II) sulfate, not blue crystals. Heat only to the point of crystallisation, then cool the solution so that crystals form, and filter, rinse and dry them.
- How do I test for hydrogen, oxygen and carbon dioxide?
- Hydrogen gives a squeaky pop with a lighted splint. Oxygen relights a glowing splint. Carbon dioxide turns limewater milky. A glowing splint is the test for oxygen, not for hydrogen.
- How do I test for chloride, bromide and iodide ions?
- Acidify the sample with dilute nitric acid, then add aqueous silver nitrate. Chloride gives a white precipitate, bromide a cream precipitate and iodide a (pale) yellow precipitate. Use nitric acid only, because hydrochloric acid contains chloride ions.
- How do I test for sulfate ions?
- Acidify the solution with dilute nitric acid, then add aqueous barium nitrate. A white precipitate shows sulfate ions. No change shows that sulfate ions are absent.
- How do I identify ammonium and nitrate ions?
- Ammonium ions give ammonia when aqueous sodium hydroxide is added and warmed, and the gas turns damp red litmus blue. Nitrate ions need aluminium foil as well: add aluminium foil and sodium hydroxide, warm, and test the gas. The ammonia can come from ammonium ions, so it does not show nitrate alone.
- How do I tell aluminium ions from zinc ions?
- Both give a white precipitate with sodium hydroxide, and both dissolve in excess. With ammonia, aluminium gives a white precipitate that stays in excess, but zinc dissolves in excess ammonia. Sodium hydroxide alone cannot separate aluminium from zinc; the ammonia test does.
- Why is a white precipitate with silver nitrate not enough to show chlorine?
- A white precipitate with silver nitrate shows chloride ions, not chlorine gas. Chlorine is shown by bleaching damp litmus paper. Some candidates confused chlorine with chloride, and hydrochloric acid contains chloride ions, so dilute nitric acid must be used.